Current-production VFDs from Allen-Bradley, Danfoss, ABB, Siemens, Yaskawa, and others. Discontinued models sourced through surplus channels. Accessories including line reactors, EMI filters, and braking resistors. Send the HP rating, voltage, and model number for a quote.
These are current-production models available through active distribution. Standard HP ratings, 240V, 480V, and 600V configurations, NEMA 1 and NEMA 4X/12 enclosures.
PowerFlex 4M and 40P for fractional through 30HP general-purpose applications. PowerFlex 400 and 520/525 for HVAC and pump/fan. PowerFlex 700 for high-performance applications. PowerFlex 755 for servo-class torque control and multi-axis applications. 240V, 480V, 600V, and 690V configurations available.
FC51 (Micro) for basic speed control applications. FC101 for HVAC: optimized for fan and pump loads with built-in pump cascade and sleep mode. FC102 for pump/fan with advanced process control. FC302 for high-dynamic applications. IP20/21, IP54, IP55, and IP66 enclosure options across the range.
ACS310 and ACS355 for general machinery. ACS580 for general-purpose industrial with built-in EMC filter options. ACS800 for high-performance industrial (direct torque control). ACS880 for process applications with advanced motor control and safety functions. Single-phase input models available in smaller frames.
V20 for simple constant-torque applications (0.12kW to 30kW). G120 for machine OEM applications with modular power and control unit architecture. G130 for higher power applications in cabinet configuration. All rated for 400/480V input in standard configurations.
V1000 for compact general-purpose applications. A1000 for vector control and high-performance processes. GA500 and GA700 for industrial applications with enhanced connectivity and safety options. Widely used in pump, fan, conveyor, and material handling applications.
Eaton DG1 for general-purpose applications (1HP to 200HP at 480V). Schneider Altivar Process 320 and 340 for pump, fan, and compressor applications. Schneider Altivar Machine ATV340 for machine OEM applications. Both lines offer standard NEMA 1 and NEMA 4X enclosure options.
Some facilities are still running VFDs from lines that have been discontinued, and replacing them with a current-production model isn't always straightforward. Parameter migration, encoder compatibility, bypass wiring, and enclosure fit all add complexity to a swap. Sometimes a facility needs a shelf spare in the same platform rather than dealing with a full changeover.
Edmundson Industrial sources discontinued VFDs through surplus and specialty channels. Condition is disclosed clearly: new-old-stock, surplus (previously purchased but unused), or take-out from working equipment. We do not warrant functionality unless explicitly stated.
The more specific your request, the faster we can check availability. Catalog number and HP/kW rating are the minimum. Enclosure type and control interface (analog, discrete, fieldbus) help us confirm the unit is a real match for your application before we quote it.
New, surplus, or reconditioned: condition disclosed clearly with every quote.
Submit a RequestAccessories are often needed alongside a new drive, or to correct issues with an existing installation. These are sized to the specific drive HP and voltage rating.
Input line reactors (3-5% impedance) protect the VFD from voltage spikes on the supply and reduce harmonic distortion back to the line. Output line reactors protect motor insulation on long cable runs and reduce common-mode noise. Sized by drive HP, input voltage, and FLA. Specify input-side or output-side.
Electromagnetic interference filters are required by some installations to meet CE or other EMC standards, or to protect sensitive equipment on the same power bus. Filter selection requires the drive model, HP, and supply voltage. Some drive families include an internal filter option; confirm before ordering external.
Dynamic braking dissipates regenerated energy when the motor decelerates. Most VFDs include an internal brake chopper (braking transistor) but require an external resistor. Braking resistors are sized by peak braking torque, duty cycle (percent braking time), and drive voltage. Braking units are needed for drives that do not include an internal chopper.
Bypass contactors allow the motor to run across the line when the VFD is out of service for maintenance. Manual bypass and automatic bypass (with speed matching logic) configurations available. Communication modules for EtherNet/IP, DeviceNet, PROFIBUS DP, Modbus RTU/TCP, and PROFINET are available for most current-production drive families; specify the protocol and the drive model when ordering.
Current-production drives quote quickly on standard configurations. Custom enclosures, special communications, or high-horsepower frames may have additional lead time. Discontinued drives depend on what's in the market at the time of the request.
Use the RFQ form or contact us directly. Include the drive model and HP for the fastest response.
Or contact directly: